52
Table 19. MIN MAX Recording Specifications
Model Nominal Response Accuracy
83 100 ms to 80 % Specified accuracy ± 12 counts for changes > 200 ms in duration
(± 40 counts in ac with beeper on)
100 ms to 80 % (dc functions) Specified accuracy ± 12 counts for changes > 200 ms in duration
120 ms to 80 % (ac functions) Specified accuracy ± 40 counts for changes > 350 ms and inputs > 25 % of range
87
250 μs (peak) (Model 87 only)
1
Specified accuracy ± 100 counts for changes > 250 μs in duration
(add ± 100 counts for readings over 6000 counts)
(add ± 100 counts for readings in Low Pass mode)
1. For repetitive peaks: 1 ms for single events.