Fluke 1595A Manuale Utente

Navigare online o scaricare Manuale Utente per Termometri Fluke 1595A. Fluke 1595A User Manual Manuale Utente

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa

Sommario

Pagina 1 - Super-Thermometer

1594A/1595A Super-ThermometerTechnical Guide159X____tgeng0000

Pagina 2

1594A/1595A Super-Thermometer xTablesTable 1 Symbols ...

Pagina 3 - Table of Contents

1594A/1595A Super-ThermometerInterface Commands90Parameter <source> may be any of the following:<source> Function1Selects the internal 1 W

Pagina 4

91Remote OperationInterface CommandsA channel number in <channel list> may be 1 through 4 for the corresponding front channel input, 5 through 1

Pagina 5

1594A/1595A Super-ThermometerInterface Commands92Parameter <value> is the number of measurements performed on a channel before advancing to the

Pagina 6

93Remote OperationInterface CommandsPassword protection: Measure ProtectionSets the Average Enable for the sample average (see Section 5.7.3.2, TIMING

Pagina 7

1594A/1595A Super-ThermometerInterface Commands94The returned value is a resistance ratio after processing by the digital lter. If no measurement is

Pagina 8

95Remote OperationInterface Commands8.7.3.95 SYST:BEEP[:IMM]Example command: SYST:BEEPProduces an immediate beep from the speaker.8.7.3.96 SYST:BEEP

Pagina 9

1594A/1595A Super-ThermometerInterface Commands96Sets the network port’s IP Address setting (see Section 8.2, Conguring the Network (LAN) Port, on pa

Pagina 10

97Remote OperationInterface Commands8.7.3.109 SYST:COMM:SOCK:MAC?Example response: “00204A9AF1A2”Reads the network port’s Hardware MAC address (see S

Pagina 11 - 1 Before You Start

1594A/1595A Super-ThermometerInterface Commands988.7.3.116 SYST:ERR?Example response: -100,“Command error”Reads the next error in the error queue. Wh

Pagina 12 - Authorized Service Centers

99Remote OperationInterface Commands8.7.3.120 SYST:PASS:CEN:STAT?Returns the password-access state. The response is 0 if access is disabled and 1 if

Pagina 13

1Before You StartSafety Information1 Before You Start1.1 Symbols UsedTable 1 lists the symbols that may be used on the instrument or in this manual

Pagina 14

1594A/1595A Super-ThermometerInterface Commands100Query form: SYST:TIME:DAYL?Password protection: Time/Date ProtectionAlternate parameter: DEFSets the

Pagina 15 - 2.2 Specications

101Remote OperationInterface CommandsThe query form returns 1 if Ratio Self-Calibration is in progress, 0 otherwise.8.7.3.134 TEST:LIN:REP<n>?E

Pagina 16 - 2.2.2.2 Resistor Stability

1594A/1595A Super-ThermometerInterface Commands1028.7.3.138 TEST:LIN:TOL<n>?Example response: 0.8Reads a Ratio Self-Calibration test tolerance

Pagina 17

103CalibrationCURRENT TEST (F2)9 Calibration9.1 IntroductionThis section explains the step-by-step instructions for calibrating and verifying functi

Pagina 18

1594A/1595A Super-ThermometerRATIO CALIBRATION (F3)104If using a calibrated resistor, connect the resistor to all four terminals on one of the front p

Pagina 19 - 2.2.5.1 Introduction

105CalibrationRATIO CALIBRATION (F3)sured resistance ratios. Ideally the product would be exactly 1.0. The reported error is half the difference of th

Pagina 20 - Specications

1594A/1595A Super-ThermometerRESISTANCE CALIBRATION (F4)106The reported data of the Ratio Self-Calibration may be written to a le on a USB memory dev

Pagina 21

107CalibrationRESISTANCE CALIBRATION (F4)To properly calibrate a Super-Thermometer internal resistor, the expanded uncertainty (k = 2) of the standard

Pagina 22

1594A/1595A Super-ThermometerCALIBRATION PARAMETERS (F5)108The results of the resistance calibration are written to the le as follows:RESISTANCE,<

Pagina 23

109CalibrationCALIBRATION PARAMETERS (F5)9.6.2 Standby Current CheckIt may be necessary to check standby current to ensure proper operation. The stan

Pagina 24

1594A/1595A Super-ThermometerAuthorized Service Centers2 DO NOT connect an AC mains supply that does not match the voltage setting on the back of the

Pagina 26 - 3.4 Connecting to Line Power

111Maintenance 10 MaintenanceAvoid operating the instrument in excessively wet, oily, dusty, or dirty environments. If the outside of the instrument

Pagina 28 - 4.2.3 Front Panel Keys

113Troubleshooting 11 TroubleshootingThe purpose of this section is to help the user troubleshoot unexpected operation results. Use the following lis

Pagina 29 - 4.2.3.1 Front Panel Display

1594A/1595A Super-Thermometer 114Problem SolutionPoor accuracy The current may be too low causing poor signal to noise ratio or too high causing exce

Pagina 30 - 4.3 Rear Panel Features

115 IndexSymbols1.4142 30, 4310/100 Base T Ethernet 6524-hour format 502590 Scanner 20°C 50, 56, 108°F 50, 56, 108AABSOLUTE ERROR 107Absolute

Pagina 31

1594A/1595A Super-Thermometer 116DATE FORMAT 47, 57Daylight Saving 100DAYLIGHT SAVING 51, 58DECIMAL FORMAT 47, 57decimal point 18Decimal setting

Pagina 32 - Figure 6 Power Entry Module

117 Interface Commands 70INTERNAL 53Internal Memory 41, 42Internal Resistor Calibration 108IP address 51, 66IP Address 96IP ADDRESS 51ISO Guid

Pagina 33 - 5 Menus and Screens

1594A/1595A Super-Thermometer 118PHASE 45POLARITY 104POLYNOMIAL 35, 36PORT ENABLE 51, 52, 69port number 65Power Entry Module 15Power Standby key

Pagina 34 - 5.5 Menu System

119 Scanner Connection 20scanning 90Scanning 62SCAN SETTINGS (F1) 39Screens 23Screen Saver 47SCREEN SAVER DELAY 47, 57SCREEN SAVER ENABLE 47,

Pagina 35 - Measurement Screen

3Before You StartAuthorized Service CentersFluke South East Asia Pte Ltd.Fluke ASEAN Regional OfficeService Center60 Alexandra Terrace #03-16The Comtec

Pagina 36 - Figure 9

1594A/1595A Super-Thermometer 120TRACE 50T(R) POLYNOMIAL 36TYPE 34UUnit 56UNIT 50unlimited 79UNLIMITED 49Unlimited mode 49Unpacking 15UPDATE

Pagina 38 - 5.7 Main Menu

5Introduction and SpecicationsSpecications2 Introduction and Specications2.1 IntroductionThe Fluke family of Hart Super-Thermometers long ago est

Pagina 39 - MAIN MENU

1594A/1595A Super-ThermometerSpecications6Primary Specications: the core set of measurement accuracy specications of the Super-Thermometer. They ar

Pagina 40

7Introduction and SpecicationsSpecicationsTable 3 Resistor Stability SpecificationsResistor (Rs) Accuracy (ppm of reading), 95% condence level24 ho

Pagina 41 - Main Menu

1594A/1595A Super-ThermometerSpecications8Table 5 Measurement Current Accuracy SpecificationsCurrent Range Accuracy99% condence level, 1-year0.001 mA

Pagina 42

9Introduction and SpecicationsSpecications2.2.4 General SpecicationsTable 8 General SpecificationsWarm-up period 30 minutesMeasurement range 0W to

Pagina 43

Fluke Corporation799 E. Utah Valley Drive • American Fork, UT 84003-9775 • USAPhone: +1.801.763.1600 • Telefax: +1.801.763.1010E-mail: support@hartsci

Pagina 44 - MAIN MENU

1594A/1595A Super-ThermometerSpecications10When calibrating an SPRT on the ITS-90, the WT90 value is measured at required xed-point temperatures. Th

Pagina 45

11Introduction and SpecicationsSpecicationsis converted to temperature by dividing 0.03 ppm by 1.0 × 106 and then multiplying by 1.02. The result is

Pagina 46

1594A/1595A Super-ThermometerSpecications12of the SPRT at 157 °C which is 0.1 Ω/°C (see tip above). This results in a standard temperature uncertaint

Pagina 47

13Introduction and SpecicationsSpecications2.2.5.4.2 Example 3: Measuring Zero-Power ResistanceThe purpose of this example is to demonstrate how th

Pagina 48 - Figure 12 Measure Menu Screen

1594A/1595A Super-ThermometerSpecications14257 Ω. Divide the result by the sensitivity of the PRT (dR/dT) at 420 °C. This can be found in the PRT cal

Pagina 49 - 5.7.3.2 TIMING SETTINGS (F2)

15Preparation for OperationLine Voltage and Fuses3 Preparation for Operation3.1 Unpacking and InspectionThe Super-Thermometer is shipped in a contai

Pagina 50

1594A/1595A Super-ThermometerConnecting to Line Power161. Disconnect line power.2. Observe what line voltage setting is displayed in the PEM window.

Pagina 51

17Front and Rear Panel FeaturesFront Panel Features4 Front and Rear Panel Features4.1 IntroductionThe Super-Thermometer has been designed with sever

Pagina 52

1594A/1595A Super-ThermometerFront Panel Features184.2.3 Front Panel KeysTable 10 Front panel key descriptionsThe Power Standby key turns off the dis

Pagina 53

19Front and Rear Panel FeaturesFront Panel Features4.2.3.1 Front Panel DisplayThe Front Panel Display is shown in Figure 3. The display screen is use

Pagina 54

iii Table of Contents1 Before You Start ... 11.1 Symbols Used ...

Pagina 55 - CHAN,<channel number>

1594A/1595A Super-ThermometerRear Panel Features204.3 Rear Panel FeaturesFigure 4 Rear view4.3.3.1 External Resistor InputsFigure 5 External Resisto

Pagina 56 - Figure 14 Display Menu Screen

21Front and Rear Panel FeaturesRear Panel Features4.3.2 Future Peripheral ConnectionA USB peripheral port is intended for future peripheral control.

Pagina 57 - MAIN MENU

1594A/1595A Super-ThermometerRear Panel Features224.3.4 Line Voltage ConnectionFigure 6 Power Entry ModuleThe PEM (Power Entry Module) located on th

Pagina 58 - 5.7.4.2 FIELD SETTINGS (F2)

23Menus and ScreensChanging Settings5 Menus and Screens5.1 IntroductionThis section provides detailed description of the Super-Thermometer menus and

Pagina 59 - 5.7.4.4 GRAPH SETTINGS (F4)

1594A/1595A Super-ThermometerPassword Protection24In the Alpha-Numeric Interface, use the front panel arrow keys to move the cursor to the desired cha

Pagina 60 - Figure 15 System Menu Screen

25Menus and ScreensMeasurement Screen | | | READ RESISTOR | | MANAGE RESISTORS | | READ FILE | | WRITE FILE | |

Pagina 61

1594A/1595A Super-ThermometerMeasurement Screen26or by pressing and releasing the MENU key then pressing the EXIT key. The following describe each sec

Pagina 62

27Menus and ScreensMeasurement ScreenOVEN - indicates whether the resistor oven is stable and ready for measurement. After power up, the OVEN eld wil

Pagina 63 - 5.7.5.3.1 STORE CONFIG (F1)

1594A/1595A Super-ThermometerMain Menu285.6.6 START/STOP MEASUREMENT (F1)The Start/Stop Measurement function key is a toggling function key that star

Pagina 64

29Menus and ScreensMain MenuDISPLAY MENU - used to congure display settings, and statistics settings as well as selecting temperature measurement uni

Pagina 65

1594A/1595A Super-Thermometer iv4.3.5 Earth Ground Connection ...

Pagina 66

1594A/1595A Super-ThermometerMain Menu305.7.1.2 CHANNEL SETTINGS (F2)MAIN MENU | CHANNEL SETUP | With the desired channel selected in the Channel Set

Pagina 67 - 6 Getting Started

31Menus and ScreensMain Menu5.7.1.2.1 SET UP Rs (F1)MAIN MENU | CHANNEL SETUP | CHANNEL SETTINGS |Pressing the Set Up Rs function key displays the Rs

Pagina 68 - Figure 16 Input Wiring

1594A/1595A Super-ThermometerMain Menu325.7.1.2.1.1.3 EDIT RESISTOR (F2) MAIN MENU | CHANNEL SETUP | CHANNEL SETTINGS | SET UP Rs | DEFINE RESISTOR |

Pagina 69

33Menus and ScreensMain Menuwrite the le. If a USB memory device has not yet been inserted, the user is instructed to do so. Allow about 10 seconds f

Pagina 70

1594A/1595A Super-ThermometerMain Menu345.7.2 PROBE MENU (F2)MAIN MENU |Figure 11 Probe Menu ScreenThe Probe Menu contains the function keys needed f

Pagina 71 - 7 Making Measurements

35Menus and ScreensMain MenuCALIBRATION DATE - the calibration date of the probe. The digits may be set to zero if the date is undened.NOMINAL CURREN

Pagina 72

1594A/1595A Super-ThermometerMain Menu36Type Conversion Coefficients EquationsTHERMISTOR R(T) POLYNOMIAL B0, B1, B2, B3RBtiii[] exp[] .Ω=+

Pagina 73

37Menus and ScreensMain Menu5.7.2.4 READ PROBE (F4)MAIN MENU | PROBE MENU |The Read Probe function key allows the user to read a probe denition from

Pagina 74

1594A/1595A Super-ThermometerMain Menu38If the \159x\probe\ folder and .prb le have not been created previously, they will be created automatically w

Pagina 75 - 8 Remote Operation

39Menus and ScreensMain MenuThe following are complete descriptions of each function key.5.7.3.1 SCAN SETTINGS (F1)MAIN MENU | MEASURE MENU |Scan Set

Pagina 76

v 6.2 User Settings Screen ...576.3 Connecting a Probe

Pagina 77

1594A/1595A Super-ThermometerMain Menu4041) if the digital filter is ON. If the digital filter is OFF, measurement samples are passed directly to Conver

Pagina 78 - 8.4 Conguring the USB Port

41Menus and ScreensMain MenuPRESET PRECISION (F2) - sets the timing settings for minimal measurement noise and settling error with most thermometer pr

Pagina 79 - Conguring the IEEE-488 Port

1594A/1595A Super-ThermometerMain Menu42Important: Avoid switching power off to the Super-Thermometer while measurement and recording are in progress

Pagina 80 - 8.7 Interface Commands

43Menus and ScreensMain Menu5.7.3.4.3 READ FILE (F3) MAIN MENU | MEASURE MENU | RECORDING MENU |The Read File function key allows the user to view me

Pagina 81 - Remote Operation

1594A/1595A Super-ThermometerMain Menu44Tip: Zero-Power measurements must be performed in a very stable heat source so temperature drift does not inte

Pagina 82

45Menus and ScreensMain MenuCHANNEL - the measurement channelPROBE - the ID of the probe TIME REMAINING - the amount of time left to complete the zero

Pagina 83

1594A/1595A Super-ThermometerMain Menu46PROBE,<probe ID>ZERO_MEAS,<corrected measurement>,<unit>SELF_HEAT,<self heating>,<u

Pagina 84

47Menus and ScreensMain Menu5.7.4.1 USER SETTINGS (F1)MAIN MENU | DISPLAY MENU |The User Settings screen allows the user to set preferences such as l

Pagina 85 - 8.7.3.6 *SRE <value>

1594A/1595A Super-ThermometerMain Menu48When the User Settings screen appears after power-on, when the Start-Up Help setting is ON, the User Set-tings

Pagina 86

49Menus and ScreensMain Menu5.7.4.3 STATISTICS SETTINGS (F3)MAIN MENU | DISPLAY MENU |The Statistics Settings screen allows the user to set statistic

Pagina 87

1594A/1595A Super-Thermometer vi8.7.3.24 CALC<n>:DELT:DATA? ...

Pagina 88

1594A/1595A Super-ThermometerMain Menu50TRACE - controls whether a measurement point is plotted with a line that connects to the previous point or as

Pagina 89

51Menus and ScreensMain MenuDAYLIGHT SAVING - determines whether the clock is automatically adjusted at the beginning and end of the Daylight Saving p

Pagina 90

1594A/1595A Super-ThermometerMain Menu52SUBNET MASK - species the network’s subnet mask when DHCP is OFF. Gateway and Subnet Mask are not available w

Pagina 91

53Menus and ScreensMain Menu5.7.5.3.1 STORE CONFIG (F1)MAIN MENU | SYSTEM MENU | CONFIG |The Store Conguration function allows the user to store set

Pagina 92

1594A/1595A Super-ThermometerMain Menu545.7.7 DELETE CONFIG (F3)MAIN MENU | SYSTEM MENU | CONFIG |The Delete Conguration function may be used to del

Pagina 93

55Menus and ScreensMain MenuRESISTOR PROTECTION - enables or disables protection of resistor denition related screens. This setting is useful for ens

Pagina 94

1594A/1595A Super-ThermometerMain Menu56In the Calibration Parameters screen the user may view and change measurement calibration settings. The calibr

Pagina 95

57Getting StartedUser Settings Screen6 Getting Started6.1 Powering on the Super-ThermometerCAUTION: Before powering the Super-Thermometer on, ensure

Pagina 96

1594A/1595A Super-ThermometerConnecting a Probe or Resistor58KEYPAD BEEP- enables (ON) or disables (OFF) the audio indication that accompanies each ke

Pagina 97

59Getting StartedConnecting a Probe or ResistorThe DWF connectors are labeled with C1, C2 (current connections) and P1, P2 (measurement potential con-

Pagina 98

vii 8.7.3.80 SENS:APER[:DISP] <time> ...928.

Pagina 100 - 8.7.3.72 ROUT:CLOS:STAT?

61Making MeasurementsMeasuring a Temperature Probe7 Making Measurements7.1 IntroductionThe Super-Thermometer has been designed to allow quick and ea

Pagina 101 - Interface Commands

1594A/1595A Super-ThermometerScanning Multiple Temperature Probes627. If the desired measurement channel is set to Off, use the ON/OFF (F3) function

Pagina 102

63Making MeasurementsMaking A Zero-Power Measurementc. Select the SETUP RS (F1) function key.d. Select the DEFINE RESISTOR (F2) function key.e. Sel

Pagina 104

65Remote OperationConguring the Network (LAN) Port8 Remote Operation8.1 IntroductionThis section contains instructions for controlling the Super-Th

Pagina 105

1594A/1595A Super-ThermometerConguring the Network (LAN) Port66Conguring the LAN port is accomplished through the Remote Interface section of the Sy

Pagina 106

67Remote OperationConguring the Network (LAN) Port1. In the NETWORK screen, use the Up/Down arrow keys to select DHCP ENABLE.2. IF DHCP is set to O

Pagina 107

1594A/1595A Super-ThermometerUsing the Web Interface681. In the NETWORK screen, use the Up/Down arrow keys to select HOST NAME.2. While HOST NAME is

Pagina 108

69Remote OperationConguring the IEEE-488 Port1. Press the MENU key.2. Select the SYSTEM MENU (F5) function key3. Select the REMOTE INTERFACE (F2)

Pagina 109

1594A/1595A Super-Thermometer viii8.7.3.136 TEST:LIN[:STAT]? ...

Pagina 110

1594A/1595A Super-ThermometerInterface Commands708.7 Interface CommandsAn alphabetical listing of the commands implemented by the Super-Thermometer i

Pagina 111 - 8.7.3.137 TEST:LIN:TIME?

71Remote OperationInterface CommandsCommand FunctionAssociated Setting or Function (screen)CAL:DATE Sets the instrument’s date of calibration Calibrat

Pagina 112

1594A/1595A Super-ThermometerInterface Commands72Command FunctionAssociated Setting or Function (screen)INIT:CONT Starts or stops measurement START/ST

Pagina 113 - 9 Calibration

73Remote OperationInterface CommandsCommand FunctionAssociated Setting or Function (screen)SENS:APER:PRES Sets the measurement timing settings to pres

Pagina 114 - 9.4 RATIO CALIBRATION (F3)

1594A/1595A Super-ThermometerInterface Commands74Command FunctionAssociated Setting or Function (screen)SYST:PASS:GROU:RES Sets the password Resistor

Pagina 115 - RATIO CALIBRATION (F3)

75Remote OperationInterface CommandsBit Event0 OPC, Operation Complete1 Request control (not used)2 Query error3 Device dependent error4 Execution err

Pagina 116 - RESISTANCE CALIBRATION (F4)

1594A/1595A Super-ThermometerInterface Commands76Query form: *SRE?Sets the Service Request Enable register. This mask register determines which corres

Pagina 117

77Remote OperationInterface CommandsSets the calibration Zero Correction parameter.This setting may be used to apply a zero correction to the measurem

Pagina 118 - CALIBRATION PARAMETERS (F5)

1594A/1595A Super-ThermometerInterface Commands78Query form: CALC:AVER:COUN?Alternate parameter: DEF, MIN, MAXSets the statistics Sample Count setting

Pagina 119

79Remote OperationInterface Commands8.7.3.19 CALC<n>:AVER:SEM?Example command: CALC3:AVER:SEM?Example response: 0.000039Reads a channel’s stati

Pagina 120

ix FiguresFigure 1 PEM (Power Entry Module) ...16Figure 2 Front view ..

Pagina 121 - 10 Maintenance

1594A/1595A Super-ThermometerInterface Commands80Sets the Delta Channel setting (see Section 5.7.4.3, STATISTICS SETTINGS (F3), on page 49).Parameter

Pagina 122

81Remote OperationInterface Commands8.7.3.29 DATA:REC:FILE <name>Query form: DATA:REC:FILE?Sets the data recording USB File name (see Section 5

Pagina 123 - 11 Troubleshooting

1594A/1595A Super-ThermometerInterface Commands82Reads a statistics eld setting of the visible statistics elds memory set (see Section 5.7.4.2, FIEL

Pagina 124 - 1594A/1595A Super-Thermometer

83Remote OperationInterface CommandsSets the display Rs Due Alert enable (see Section 5.7.4.1, USER SETTINGS (F1), on page 47). The default setting is

Pagina 125

1594A/1595A Super-ThermometerInterface Commands84Alternate parameter: DEF, MIN, MAXSets the stop timer’s Timer Duration setting (see Section 5.7.3.2,

Pagina 126

85Remote OperationInterface CommandsAdds a new probe denition to the Probe Library. Before a probe can be assigned to a channel and tem-perature meas

Pagina 127

1594A/1595A Super-ThermometerInterface Commands86Reads the ID of the next probe in the Probe Library. It also advances the library index used for the

Pagina 128

87Remote OperationInterface CommandsC0 – C7 C0 – C7 exponential numberThermistor type settingsMaximum Temperature MAX_TEMP decimal number, dependent o

Pagina 129

1594A/1595A Super-ThermometerInterface Commands88A channel’s Calculation setting will be changed from temperature to resistance (see Section 8.7.3.27,

Pagina 130

89Remote OperationInterface CommandsSets the resistor denition assigned to a front reference resistor input. (Use the command INP:REAR<n>:RS:ID

Modelli collegati 1594A

Commenti su questo manuale

Nessun commento